|
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
H20-8600 SERIES LIQUID COOLING KITS -
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
IntroductionThe H20-8600 series liquid cooling kits continue our tradition of truly plug-and-play components with the added performance and value of the new generation of MCW6000 water-blocks. These kits are specifically intended to bring the efficiency, and quiet operations of liquid cooling to confined environments. They require no case modifications, and may be installed with all existing components already in place inside the chassis (*) The H20-8600 series kits include a number of options to accomodate most configurations, from mild to extreme cooling, and they are ideally suited for any chassis featuring 80mm fan intake and/or exhaust openings. Performance features:
Convenience & reliability features:
Optional devices and configurations:
Examples of installation on an AMD® K7 platform. Picture 1 includes andMCW6000-A CPU cooler, MCW20-A chipset cooler, and MCW50 VGA cooler, and picture 2 is the same setup with an extra MCR80-F2 radiator. Note the tight and "clean" radii that can be achieved with the coolsleeves coils. ..and the dual radiator setup |
||||||||||||||||||||||||||||||||||||
Performance dataTo characterize the kits' performance with different configurations, each kit was installed in a bare chassis with a heat die simulator and then tested in an environmental chamber where the radiator fan inlet air temperature was held at 25.00°C ±0.02. The thermal resistance of the system could then be characterized by the difference between the fan's inlet air temperature and the heat die, divided by the heat load in Watts; such ratio is commonly referred to as the "C/W". The results below are accurate and comparable
as the only variables were the radiators, and fan voltages.
When the MCW20 and MCW50 were added, a 50% higher heat
load was induced in order to simulate the combined heat
load produced by a high-end VGA adapter and a Northbridge
chipset.
*actual Watts measured at heater of die simulator / estimated processor load per "Radiate" (CPU wattage estimation program) or similar
**Noting that C/Ws are specific to an individual test bench (due to the lack of standard test methods); the system C/Ws described are those actually determined with a kit using our heat die simulator as a heat source and mounted in a chassis, placed in an environmental chamber where the radiator fan inlet air temperature was held at 25.00°C ±0.02.
From the above several generalizations can be made:
|
||||||||||||||||||||||||||||||||||||
|
|
||||||||||||||||||||||||||||||||||||
INDIVIDUAL AND OPTIONAL COMPONENTS SPECIFICATIONS
MCR80-F2 Radiator assembly
FBK525 Fill & bleed assemblyThis 1/2" fill & bleed kit replaces a reservoir. It fits in any 5 1/4" bay, and occupies only one slot. Thanks to convenient retention clips, the FBK-525 can be installed just about anywhere in the computer. New inlet and discharge ball valves also offer added convenience for quick and easy insertion and removal of the tubes. The FBK525 allows users to fill the cicuit with coolant, and conveniently bleed it of any air bubles. The kit ships with two 2 1/2ft long, 1/2" tubes for fill and bleed operations. Inherent advantages of this kit compared to previous versions are:
Advantages of such kit versus 5 1/4" reservoirs are also multiple:
|
||||||||||||||||||||||||||||||||||||
|
(*) to the exception of the optional chipset cooler, which requires removal of the motherboard. |
||||||||||||||||||||||||||||||||||||
Contents |
|
| > | Introduction |
| > | Performance Data |
|
>
|
Components specifications |
|
>
|
MCR80-F1 Radiator |
|
>
|
FBK525 Integrated d F&B kit assy. |
| > | Customizing your own kit |
|
>
|
Versions |
| > | MSRP |
|
>
|
MCR80-F2 radiator installation guide
|
| > | |
![]()