H20-8501™ SERIES LIQUID COOLING KITS

CONTINUED...

CUSTOMIZING YOUR OWN KIT FROM VARIOUS COMPONENTS

  • Adding a second radiator is easy, and recommended in the following scenarios:

    • Dual CPU setup: while operating dual CPU's with the basic single radiator kit is possible, the extra thermal load placed on the cooling system might require installing a stronger fan than that delivered with the kit, thus increasing audible noise. Adding a second radiator to the loop restores the proper balance between high performance and low noise offered by the basic H20-8501 kit.
    • Extreme Overclocking: for enthusiast users seeking to squeeze extra Mhz from their microprocessors.
    • Extremely quiet operations: where silent operations are preferred, adding a second ratiator will allow users to operate the fans at low speed, using a rheostat for example, while maintaining optimum processor temperature, even under substantial overclocks.

      For optimum performance, it is imperative to connect two radiators in a "parallel" configuration, and not in series. Starting from any section of the circuit, use a "Y" connector to split the line in two , and connect each branch to the inlet of each radiator. Then connect each outlet tube from the radiators to a second "Y" and re-attach the discharge from the Y to the rest of the circuit. A second radiator installed in such a way will afford a CPU temperature improvement of 5°Cto 7°C.

  • Adding a second water-block for multiprocessor environments is even easier, as water-blocks need only to be connected in series: the discharge from one to the inlet of the other.

  • Adding VGA and/or chipset coolers follows the same rule as adding a second water-block: simply daisy chain the devices in series following the CPU water-block.

    Note concerning high-end VGA adapters, such as ATI® Raideon® 9700/9800 or nVidia® FX58/5900: it is suggested that adding a second radiator to the circuit will also enable higher overclocks with such graphic adpaters.

  • Configuring the kit for 3/8" OD tubing: while it must be noted that 3/8" OD tubing will significantly reduce coolant flow-rate and affect cooling performance, such a configuration is possible, and sufficient in non or mildly overclocked systems: for example when users are mainly concerned with quiet operations. The following parts are then needed to adapt the kit to 3/8" OD tubing:

    • Radiator:
      Part # PI0412S

    • Pump, fill & bleed kit, and water-blocks: simply plug-in the following adapter into each 1/2" fitting, to reduce them to 3/8":
      Part # PI061612S

VERSIONS

H20-8501-A

Part # H20-8501A for AMD® processors, includes:

  • MCW5000-A™ release 2 water-block compatible with:
    • AMD® Duron®, Athlon®, MP & XP, socket 462
    • Intel® Pentium® 3, socket 370
  • MCR80-F1 Radiator with (1) 80x80x25mm fans rated at 31.4 CFM (28dbA), (2) nylon clamps
  • MCP600™ 12 Volts DC industrial pump connects directly to computer power supply
  • FBK525™ fill and bleed kit assembly
  • 12 feet 1/2" vinyl tubing, and tube inserts
  • 2 Oz bottle HydrX™ extreme duty coolant
  • Arctic Alumina™ thermal paste

Part # H20-8501P for Intel® Pentium® 4 processors includes:

  • MCW5000-P™release 2 Intel® Pentium® 4, socket 478 compatible water-block
  • MCR80-F1 Radiator with (1) 80x80x25mm fans rated at 31.4 CFM (28dbA), (2) nylon clamps
  • MCP600™ 12 Volts DC industrial pump connects directly to computer power supply
  • FBK525™ fill and bleed kit assembly
  • 12 feet 1/2" vinyl tubing, and tube inserts
  • 2 Oz bottle HydrX™ extreme duty coolant
  • Arctic Alumina™ thermal paste

 

Part # H20-8501X for Intel® Xeon™ processors includes:

  • MCW5000-X™ release 2 Intel® Xeon™ compatible water-block
  • MCR80-F1 Radiator with (1) 80x80x25mm fans rated at 31.4 CFM (28dbA), (2) nylon clamps
  • MCP600™ 12 Volts DC industrial pump connects directly to computer power supply
  • FBK525™ fill and bleed kit assembly
  • 12 feet 1/2" vinyl tubing, and tube inserts
  • 2 Oz bottle HydrX™ extreme duty coolant
  • Arctic Alumina™ thermal paste

 

Part # H20-8501-64 for AMD® Athlon® 64 & Opteron® processors includes:

  • MCW5000-64™ AMD® Athlon® 64 & Opteron® compatible water-block
  • MCR80-F1 Radiator with (1) 80x80x25mm fans rated at 31.4 CFM (28dbA), (2) nylon clamps
  • MCP600™ 12 Volts DC industrial pump connects directly to computer power supply
  • FBK525™ fill and bleed kit assembly
  • 12 feet 1/2" vinyl tubing, and tube inserts
  • 2 Oz bottle HydrX™ extreme duty coolant
  • Arctic Alumina™ thermal paste

Part # H20-8501B "Bare" kit without water-block includes:

  • MCR80-F1 Radiator with (1) 80x80x25mm fans rated at 31.4 CFM (28dbA), (2) nylon clamps
  • MCP600™ 12 Volts DC industrial pump connects directly to computer power supply
  • FBK525™ fill and bleed kit assembly
  • 12 feet 1/2" vinyl tubing, and tube inserts
  • 2 Oz bottle HydrX™ extreme duty coolant
  • Arctic Alumina™ thermal paste

 

Manufacturer Suggested Retail Pricing

H20-8501 series liquid cooling kits
Part #

Processor compatibility

MSRP
US $
H20-8501A™ AMD® socket A, Intel® socket 370, complete kit
$230.00
H20-8501P™ Intel® Pentium® 4, complete kit
$230.00
H20-8501X™ Intel® Xeon™, complete kit
$230.00
H20-850164™ AMD® Athlon® 64 & Opteron® , complete kit
$230.00
H20-8501B™ Bare kit, no water-block included.
$177.00
Add-On components & accessories
Part #
Description
MSRP
US $
MCW5000-A™ CPU Water-block Assembly for AMD® socket A, Intel® socket 370
$53.00
MCW5000-P™ CPU Water-block assembly for Intel® Pentium® 4
$53.00
MCW5000-X™ CPU Water-block assembly for Intel® Xeon™
$53.00
MCW5000-64™ CPU Water-block Assembly for AMD® Athlon® 64 and Opteron®
$53.00
MCW50™ VGA Water-block assembly for ATI & nVidia VGA
$38.95
MCW50-FX ™ MCW50 adapter kit for FX5800 and up series VGA
$6.50
MCW20-A™ Chipset water-block for AMD® platforms
$32.95
MCW20-P™ Chipset water-block for Intel® platforms
$32.50
MCW20-R™ Chipset water-block for AMD® and Intel® platforms
$37.95
FBK525™ R2 Fill & Bleed kit 525 fits in 5 1/4" bay
$28.50
MCR80-F1™ Radiator with (1) 80x80x25mm fan
$59.95
MCR80™ Radiator alone
$46.50
Y Connector kit 3/8" barb "Y" connector
$2.60
MCP600™ 12 Volts Industrial Pump
$84.95
MCP600-RK Reducer kit 1/2" barb to 3/8" ID tubing
$2.21
Spring inserts 0.375" OD spring extendable to 5" length
$.85

Please consult your Swiftech distributor prior to ordering direct from us, or purchase the product factory direct here